1. Check that all pump connecting bolts are tight, that there are no leaks at any interfaces, that the foundation bolts are not loose, and that the grounding is in good condition.
2. Check the installation and tension of the V-belt. Rotate the pump 2-3 times to check for any jamming during rotation.
3. Check that the bearing lubrication is normal. For pumps that have been out of service for a long time or newly installed pumps, add grease as required before starting.
4. Check that the pressure gauges on the inlet and outlet pipelines are normal, and check that the electrical system is normal.
5. For newly installed pumps or pumps after repair, briefly start the motor to check that the rotation direction of the motor and pump markings is consistent.
6. Open the inlet valve and the exhaust valve to prime the pump, removing as much air as possible from inside.
7. Confirm that the pump inlet valve and pump outlet valve are open, and confirm that the process flow before and after the pump is unobstructed.


Start-up
1. After all professional confirmations are completed, start the pump. While monitoring the pressure, close the return valve and observe the pump's operation. 2. After starting the pump, check the pump outlet pressure; it should be within the performance specifications.

3. Check the pump's operation; there should be no harsh noise or severe vibration.

4. During continuous operation, check if the bearing end cover temperature is normal; it should not exceed 40°C above ambient temperature, and should not be hot to the touch. If it is, stop the machine and check.

5. During operation, operators must not leave the site and must monitor the pump's operation, frequently checking the pump casing and outlet temperature for any changes. If any changes occur, the cause should be investigated immediately.

6. Stop the pump first, then close the outlet valve or inlet valve. For pumps that will be out of service for a long time, drain the liquid from the pump, wipe the inner and outer rotors dry, and reinstall them for storage.

Send Inquiry